Wrimco Waterproofing                              Home  | Specification | Product | Project | Technical data A-Z | Contact us

Adhesive Membrane

Anti-root Membrane

Approved Applicators

Backing Rod

Drainage Cell

Drainage Sheet

Epoxy Adhesive

Epoxy Flooring

Flat Roof Membrane  

Foundation Membrane

Liquid Membrane

Membrane Protection

Product Application

Product Category

Retaining Wall

SBS Sheet Membrane

Torch on Membrane

Under Slab Membrane

Vapour Barriers

Waterproofing Primer

 

Waterproof Balcony Liquid Membrane Waterproof Bathroom liquid membrane Waterproof Retaining Wall Liquid Rubber Membrane How to waterproof a bathroom Waterproof Internal Wet Area Membrane Waterproof Tiled Balcony Clear Penetrating Sealer Trafficable liquid membrane UV Protection liquid membrane Waterproof Water Feature liquid membrane Hydro Pressure Resistant liquid membrane Waterproof fish pond liquid membrane waterproof bathroom liquid membrane Waterproof above screed liquid membrane UV Resistant Polyurethane Membrane Waterproof leaking balcony liquid membrane waterproof damp basement wall liquid membrane Solutions to common waterproofing problems Maxseal Foundation Polyurethane Membrane MasterSeal M210TIX Latex Rubber Liquid Membrane Waterproof wet basement wall liquid membrane Injection Drill Pump Vulkem 350/345/346 Ardex WPM 300 Epoxy - Stop Rising Damp Waterproof Metal Roof Liquid Membrane Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer, waterproof Leaking Balcony, Flat Roof, Planter Box, Bathroom tradesman, handyman Waterproof Box gutter liquid membrane Waterproof Retaining Wall liquid membrane Waterproof Internal, External Wall Liquid Membrane Waterproof Concrete Slab Liquid Membrane Waterproof Balcony Liquid Membrane Stop Leaking Shower Liquid Membrane How to waterproof a retaining wall How to waterproof a Retaining Wall How to fix leaking fish pond Waterproof Garage Roof Liquid Rubber Membrane Waterproof water tanks for drinkable water Waterproof Leaking Roof, Gutters, Balcony, Car Park tradesman Waterproof leaking box gutters tradesman Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer   Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer   HiBuild Hydrastatic Water based Epoxy Hydrostatic Negative Pressure Water Based Epoxy Under tile screed bed waterproofing membrane Prevent and Fix Rising Damp Waterproofing Epoxy Waterproof exposed balcony liquid membrane Repair leaking balcony waterproof liquid membrane Waterproof Bathroom Liquid Membrane Planter Box Retaining Wall Tanking Liquid Membrane Waterproof Leaking Metal Roof Waterproofer HOw to repair leaking fish pond Waterproof Underground wall Liquid Membrane Waterproof Planter Box liquid membrane Waterproof Watertanks Cementitious Liquid Membrane Waterproof Lift Pit Liquid Membrane ARDEX WPM 001 - Undertile Waterproofing Membrane Waterproof Planter Box Root Resistant Liquid Membrane Repair Bitumen Roof Waterproofing Liquid Membrane UV Protective Polyurethane Membrane Waterproof External Brick Wall liquid membrane Waterproof Retaining Wall Liquid Membrane Waterproof Planter Box Liquid Membrane Waterproof Wet Retaining Wall Liquid Membrane Waterproof Leaking External Wall Licensed Waterproofer Emer Clad Acrylic Liquid Membrane Waterproof Planter Box, Retaining wall liquid membrane Fast Cure Elastomeric Waterproofing Membrane Systems Waterproof Leaking Swimming pool tradesman UV Resistant Acrylic Liquid Membrane How to Waterproof a Leaking Metal Box Gutter Sikalastic 560 - Repair Bitumen membrane Roof Waterproof Lift Pits Tradesmen Waterproof Leaking Kitchen Tradesmen Waterproof Leaking Internal Basement Walls tradesman Waterproof Leaking Laundry tradesman Waterproof Leaking Deck, Verandah Tradesman Waterproof Leaking Roof, Gutters, Balcony, Car Park Tradesman Repair Bitumen Roof Liquid Rubber Membrane Waterproof Besser Block Wall with Liquid Membrane Waterproof leaking bitumen roof contractors Waterproof leaking bitumen roof contractors  Waterproof Leaking Retaining Wall, Basement Wall Tradesmen
Commercial Building Sheet Membrane Concrete Roof Sheet Membrane Waterproof Deck Sheet Membrane Entertainment building Waterproofing Membrane Waterproof Government Building Sheet Membrane Waterproof Hospital Building Sheet Membrane Waterproof Landmark Building Bitumen Membrane Waterproofing Planter Box Sheet Membrane Waterproof Plywood Roof Sheet Membrane Waterproof Residential Building Sheet Membrane Waterproof Roof Bitumen Sheet Membrane Waterproof Flat Roof Sheet Membrane Waterproof Retaining Wall Sheet Membrane Terrace waterproofing Sheet Membrane Waterproof University Building Sheet Membrane Wrimco Reference Waterproof Lift Pit Sheet Membrane Waterproof Concrete Roof Sheet Membrane Tanking Sheet Membrane Systems Vaucluse Waterproofing Project  Mosman Waterproofing Project Waterproofing Palm Beach Waterproofing Dover Height Waterproofing Darling Point Waterproofing Bellevue Hill waterproofing tradesman Knowledge Base FAQ Waterproofing Product Waterproof Leaking Garage Roof tradesman Repair SBS, APP Sheet Membrane Waterproof Concrete Slab Sheet Membrane Waterproof Leaking Garage Roof Liquid Rubber Membrane Waterproof Leaking Metal Roof Liquid Rubber Membrane Waterproof Balustrade Sheet Membrane Waterproof Commercial Building Project Bitumen Sheet Membrane Closed Cell Backing Rod Repair Crack Joints Closed cell backer rod Expansion joint backing rod Backing Rod Waterproof Leaking Roof, Balcony, Box Gutter tradesman Repair Leaking underground basement wall Waterproofer Waterproof Leaking Shower, Bathroom, Wet area Tradesman Repair Leaking Deck, Planter Box Waterproofer Waterproof Leaking Fish Pond Tradesman Waterproof Rising Damp Basement Tradesmen Roofs Waterproofed with Wrimco Sheet Membrane Waterproof Retaining walls with sheet membrane Waterproof Balcony with Sheet Membrane HDPE Self Adhesive Sheet Membrane Waterproof Commercial High Rise Building Roof Contractors Waterproof Car Park Roof with sheet membrane Ardex WPM 116 Sheet Membrane Ardex WPM 150 APP Sheet Membrane ARDEX WPM 188 SBS Garden Tanking Membrane ARDEX WPM 185 APP Sheet Membrane Ardex WPM320 Retaining Wall Sheet Membrane Waterproof Deck with torch applied Sheet Membrane ARDEX WPM612 FL TPO Fleece-Backed Roof Membrane TREMproof SBS 4000M Mineral Bituminous Membrane ARDEX WPM 1000 Weldable Waterproofing Membrane SBS Sheet Membrane Installation ARDEX WPM 3000X peel and stick membrane ARDEX WPM 750 Undertile Butynol  Waterproof Concrete Slab with Sheet Membrane ARDEX WPM 444 APP Sheet Membrane How to waterproof a Retaining wall How to waterproof a Planter Box How to waterproof a planter box How to waterproof Tiled Balcony with clear sealer How to waterproof a Shower  Ardex SRO 834 Waterproofing Specification Wrimco Sheet Membrane Waterproof elevator pits Sheet Membrane SBS Sheet Waterproofing Membrane How to waterproof balcony with sheet membrane Anti Root Sheet Membrane Vehicular Traffic Liquid Membrane Waterproof Planter Box with torch applied sheet membrane Waterproof Balconies Decks Podiums Prevent Rising Damp Hydro Static Epoxy How to waterproof a planter box 

Water Based Primer:

 
 

 

DuroARW - Water Based  Primer

 

It is a single component water based primer used to prime concrete, masonry and fibre cement sheeting surfaces. When dry, it forms a pink sealed surface suitable for the application of water based membranes. The pink colouring generally indicates priming has been undertaken, enhancing a QA procedure.

 
GENERAL

 

Coverage: 6-8 m2 / Litre

Shelf Life: 1 year

Touch Dry: 30 minutes at 25 C

Colour: Pink

 

PACKAGING

 

 20 Litres

 4 Litres

 

PRINCIPLE CHARACTERISTICS

 

 Water based

 Non hazardous

 Non Toxic

 Ease of use

 Low odour

 Simple to apply

 

USE AREAS

 

Primer for water based membranes internally. All surfaces to be sound and clean; concrete to be free of efflorescence and contamination. Apply when temperature is above 8C. Use a brush or roller for application. Clean equipment with water before it dries.

 

COVERAGE

Smooth Surface: 6-8 m2 / L

Rough / Porous Surface: 3 -4 m2 / L

 

Internal Primer DuroARW MSDS:

 

 

CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

 

 
Classified as Non-Hazardous according to criteria of NOHSC and Non Dangerous Goods according to the ADG Code

 

UN No

-

D.G. Glass

-

Pack. Group

-

HAZCHEM

-

SUB.RISK.

-

SUSDP

-

 
PROPER SHIPPING NAME: Acrylic Emulsion PRODUCT USE: Waterproof membrane primer

 

2. COMPOSITION / INFORMATION ON INGREDIENTS

 

Component

CAS No

Weight %

Acrylic Polymer

Not Required

10-30

Xylene

1330-20-7

30-60

Liquid Hydrocarbons

64742-95-6

10-30

 

See Section 8, Exposure Controls / Personal Protection

 

3. HAZARDS IDENTIFICATION

Non Flammable

 

4. FIRST AID MEASURES

 

Eyes: Immediately flush with water for 15 minutes. Seek medical attention if irritation persists. Skin: Take off all contaminated clothing. Wash contaminated area with soapy warm water. Get medical advice if irritation develops or persists. Wash contaminated clothing and clean shoes before reuse. Inhalation: Remove to fresh air. If not breathing, give artificial respiration, preferable mouth to mouth. If breathing is laboured, give oxygen and consult a physician immediately. Eyes: Immediately flush with water for 15 minutes. Seek medical attention if irritation persists. Ingestion: Consult a physician immediately. DO NOT induce vomiting. Give a glass of water to drink. If vomiting occurs, aspiration into the lungs may cause lung damage. Never give anything by mouth to an unconscious person. Advice to Doctor: Treat symptomatically

 

5. FIRE FIGHTING MEASURES

 

Flash Point

Not specified

Auto-ignition Temperature

Not specified

Lower Explosive Limit

Not specified

Upper Explosive Limit

Not specified

 

Suitable Extinguishing Media: Use dry powder, carbon dioxide or foam. Protective Equipment for Fire Fighting: Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and eyes. Unusual Fire and Explosion Hazards: No fire or explosion hazard exists.

 

6. ACCIDENTAL RELEASE MEASURES

 

Eliminate all sources of ignition. Provide sufficient ventilation. Wear appropriate personal protective equipment including gloves and safety glasses. Floor may be slippery. Do not breathe vapour. Contain spill. Do not allow into drains or waterways. Take up with absorbent material (e.g. sand, vermiculite, or commercially available inorganic absorbent). DO NOT use saw dust. Use non-sparking tools and equipment. Fill into marked, sealable containers for disposal. Dispose of empty containers in accordance with federal, state and local laws.

 

7. HANDLING AND STORAGE

 

Requirements. Handling: Observe normal standards of industrial hygiene for handling chemicals. Eliminate all sources of ignition. Use in a well-ventilated area. Avoid breathing vapour and contact with skin and eyes. Wear gloves, long sleeved shirt, and eye protection. A sensitised person should not be exposed to the product. Storage: Store in tightly sealed containers to protect from atmospheric moisture. All equipment and containers must be earthed to avoid static discharge. Store in a cool, dry area. Keep away from ignition sources such as fire, flame and sparks. Empty container warning: Do not reuse empty drums or containers unless professionally cleaned. Other Precautions: Do not eat, drink or smoke when using the product.

 

8. EXPOSURE CONTROLS / PERSONAL PROTECTION

 

Respiratory Protection : If vapours and mists occur, a respiratory protection program meeting Australian Standards AS-1716 and AS-1715 requirements must be followed whenever workplace conditions warrant a respirator's use. None required if airborne concentrations are maintained below the exposure limit listed in "Exposure Limit Information"

 

Eye Protection: Use chemical splash goggles (Australian Standard AS-1337) or approved equivalent. Eye protection worn must be compatible with respiratory protection system employed. An eye wash station and safety shower should be available in the work area.

 

Hand Protection: Impermeable gloves as necessary to prevent skin contact. E.g. nitrile or neoprene gloves.

 

Engineering Controls (Ventilation): Use local exhaust ventilation sufficient to maintain exposure levels below exposure limit concentrations. Refer to Australian Standard AS-1668

 

9. PHYSICAL AND CHEMICAL PROPERTIES

 

Appearance and colour

Milky

State

Low viscosity

Odour Characteristic

No data available

pH

Not applicable

Viscosity

No data available

Specific Gravity (Water = 1)

1.00

Vapour Density (Air = 1)

No data available

Vapour Pressure

30 mm Hg @ 25 oC

Melting Point

Not specified

Boiling Point

N/A

Solubility in Water

Miscible.

Flash Point

N/A

 

10. STABILITY AND REACTIVITY

Considered stable under normal conditions of use and handling.

 

11. TOXICOLOGICAL INFORMATION

 

Acute Data Inhalation: Not hazardous. Provide adequate fresh air. Ingestion: Mild irritant. Give water to drink. Do not induce vomiting. Seek medical advice. Skin irritation: May cause irritation resulting in redness, rash and itching. Wash thoroughly with soap and water. Eyes irritation: May cause irritation if not washed out immediately. Seek medical advice if irritation persists.

 

12. ECOLOGICAL INFORMATION

 

No available data. However, material is expected to be harmful to aquatic organisms. Keep out of waterways, drains and sewers.

 

13. DISPOSAL CONSIDERATIONS

 

Containers are hazardous when empty. Do not reuse empty drums or containers unless professionally cleaned. Do not cut, drill, grind or weld on or near empty containers. Dispose of waste and empty containers in accordance with federal, state and local laws.

 

14. TRANSPORT INFORMATION

Not classified as Dangerous Goods according to the Australian Code For The Transport Of Dangerous Goods By Road And Rail (Sixth Edition). See section 1.

 

15. REGULATORY INFORMATION

Labelling Requirements: According to Criteria of National Occupational Health and Safety Commission - Australia

 

S23

Do not breathe vapour/spray.

S24/25

Avoid contact with skin and eyes.

S16

Keep away from sources of ignition - no smoking

S26

In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.

 

16. OTHER INFORMATION

National Occupational Health and Safety Commission - Australia

Australian Code For The Transport Of Dangerous Goods By Road And Rail (Sixth Edition). The advice and information contained herein is based on the original supplier's information.
 
 

 

Waterproofing FAQ

Membrane Protection Board

Waterproofing Coating

Waterproof Drainage Sheet

Waterproofing Primer

Repair and Maintenance