Wrimco Waterproofing                              Home  | Specification | Product | Project | Technical data A-Z | Contact us

Adhesive Membrane

Anti-root Membrane

Approved Applicators

Backing Rod

Drainage Cell

Drainage Sheet

Epoxy Adhesive

Epoxy Flooring

Flat Roof Membrane  

Foundation Membrane

Liquid Membrane

Membrane Protection

Product Application

Product Category

Retaining Wall

SBS Sheet Membrane

Torch on Membrane

Under Slab Membrane

Vapour Barriers

Waterproofing Primer

 

Waterproof Balcony Liquid Membrane Waterproof Bathroom liquid membrane Waterproof Retaining Wall Liquid Rubber Membrane How to waterproof a bathroom Waterproof Internal Wet Area Membrane Waterproof Tiled Balcony Clear Penetrating Sealer Trafficable liquid membrane UV Protection liquid membrane Waterproof Water Feature liquid membrane Hydro Pressure Resistant liquid membrane Waterproof fish pond liquid membrane waterproof bathroom liquid membrane Waterproof above screed liquid membrane UV Resistant Polyurethane Membrane Waterproof leaking balcony liquid membrane waterproof damp basement wall liquid membrane Solutions to common waterproofing problems Maxseal Foundation Polyurethane Membrane MasterSeal M210TIX Latex Rubber Liquid Membrane Waterproof wet basement wall liquid membrane Injection Drill Pump Vulkem 350/345/346 Ardex WPM 300 Epoxy - Stop Rising Damp Waterproof Metal Roof Liquid Membrane Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer, waterproof Leaking Balcony, Flat Roof, Planter Box, Bathroom tradesman, handyman Waterproof Box gutter liquid membrane Waterproof Retaining Wall liquid membrane Waterproof Internal, External Wall Liquid Membrane Waterproof Concrete Slab Liquid Membrane Waterproof Balcony Liquid Membrane Stop Leaking Shower Liquid Membrane How to waterproof a retaining wall How to waterproof a Retaining Wall How to fix leaking fish pond Waterproof Garage Roof Liquid Rubber Membrane Waterproof water tanks for drinkable water Waterproof Leaking Roof, Gutters, Balcony, Car Park tradesman Waterproof leaking box gutters tradesman Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer   Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer   HiBuild Hydrastatic Water based Epoxy Hydrostatic Negative Pressure Water Based Epoxy Under tile screed bed waterproofing membrane Prevent and Fix Rising Damp Waterproofing Epoxy Waterproof exposed balcony liquid membrane Repair leaking balcony waterproof liquid membrane Waterproof Bathroom Liquid Membrane Planter Box Retaining Wall Tanking Liquid Membrane Waterproof Leaking Metal Roof Waterproofer HOw to repair leaking fish pond Waterproof Underground wall Liquid Membrane Waterproof Planter Box liquid membrane Waterproof Watertanks Cementitious Liquid Membrane Waterproof Lift Pit Liquid Membrane ARDEX WPM 001 - Undertile Waterproofing Membrane Waterproof Planter Box Root Resistant Liquid Membrane Repair Bitumen Roof Waterproofing Liquid Membrane UV Protective Polyurethane Membrane Waterproof External Brick Wall liquid membrane Waterproof Retaining Wall Liquid Membrane Waterproof Planter Box Liquid Membrane Waterproof Wet Retaining Wall Liquid Membrane Waterproof Leaking External Wall Licensed Waterproofer Emer Clad Acrylic Liquid Membrane Waterproof Planter Box, Retaining wall liquid membrane Fast Cure Elastomeric Waterproofing Membrane Systems Waterproof Leaking Swimming pool tradesman UV Resistant Acrylic Liquid Membrane How to Waterproof a Leaking Metal Box Gutter Sikalastic 560 - Repair Bitumen membrane Roof Waterproof Lift Pits Tradesmen Waterproof Leaking Kitchen Tradesmen Waterproof Leaking Internal Basement Walls tradesman Waterproof Leaking Laundry tradesman Waterproof Leaking Deck, Verandah Tradesman Waterproof Leaking Roof, Gutters, Balcony, Car Park Tradesman Repair Bitumen Roof Liquid Rubber Membrane Waterproof Besser Block Wall with Liquid Membrane Waterproof leaking bitumen roof contractors Waterproof leaking bitumen roof contractors  Waterproof Leaking Retaining Wall, Basement Wall Tradesmen
Commercial Building Sheet Membrane Concrete Roof Sheet Membrane Waterproof Deck Sheet Membrane Entertainment building Waterproofing Membrane Waterproof Government Building Sheet Membrane Waterproof Hospital Building Sheet Membrane Waterproof Landmark Building Bitumen Membrane Waterproofing Planter Box Sheet Membrane Waterproof Plywood Roof Sheet Membrane Waterproof Residential Building Sheet Membrane Waterproof Roof Bitumen Sheet Membrane Waterproof Flat Roof Sheet Membrane Waterproof Retaining Wall Sheet Membrane Terrace waterproofing Sheet Membrane Waterproof University Building Sheet Membrane Wrimco Reference Waterproof Lift Pit Sheet Membrane Waterproof Concrete Roof Sheet Membrane Tanking Sheet Membrane Systems Vaucluse Waterproofing Project  Mosman Waterproofing Project Waterproofing Palm Beach Waterproofing Dover Height Waterproofing Darling Point Waterproofing Bellevue Hill waterproofing tradesman Knowledge Base FAQ Waterproofing Product Waterproof Leaking Garage Roof tradesman Repair SBS, APP Sheet Membrane Waterproof Concrete Slab Sheet Membrane Waterproof Leaking Garage Roof Liquid Rubber Membrane Waterproof Leaking Metal Roof Liquid Rubber Membrane Waterproof Balustrade Sheet Membrane Waterproof Commercial Building Project Bitumen Sheet Membrane Closed Cell Backing Rod Repair Crack Joints Closed cell backer rod Expansion joint backing rod Backing Rod Waterproof Leaking Roof, Balcony, Box Gutter tradesman Repair Leaking underground basement wall Waterproofer Waterproof Leaking Shower, Bathroom, Wet area Tradesman Repair Leaking Deck, Planter Box Waterproofer Waterproof Leaking Fish Pond Tradesman Waterproof Rising Damp Basement Tradesmen Roofs Waterproofed with Wrimco Sheet Membrane Waterproof Retaining walls with sheet membrane Waterproof Balcony with Sheet Membrane HDPE Self Adhesive Sheet Membrane Waterproof Commercial High Rise Building Roof Contractors Waterproof Car Park Roof with sheet membrane Ardex WPM 116 Sheet Membrane Ardex WPM 150 APP Sheet Membrane ARDEX WPM 188 SBS Garden Tanking Membrane ARDEX WPM 185 APP Sheet Membrane Ardex WPM320 Retaining Wall Sheet Membrane Waterproof Deck with torch applied Sheet Membrane ARDEX WPM612 FL TPO Fleece-Backed Roof Membrane TREMproof SBS 4000M Mineral Bituminous Membrane ARDEX WPM 1000 Weldable Waterproofing Membrane SBS Sheet Membrane Installation ARDEX WPM 3000X peel and stick membrane ARDEX WPM 750 Undertile Butynol  Waterproof Concrete Slab with Sheet Membrane ARDEX WPM 444 APP Sheet Membrane How to waterproof a Retaining wall How to waterproof a Planter Box How to waterproof a planter box How to waterproof Tiled Balcony with clear sealer How to waterproof a Shower  Ardex SRO 834 Waterproofing Specification Wrimco Sheet Membrane Waterproof elevator pits Sheet Membrane SBS Sheet Waterproofing Membrane How to waterproof balcony with sheet membrane Anti Root Sheet Membrane Vehicular Traffic Liquid Membrane Waterproof Planter Box with torch applied sheet membrane Waterproof Balconies Decks Podiums Prevent Rising Damp Hydro Static Epoxy How to waterproof a planter box 

Commercial Roofing Insulation Board: 


ARDEX Polyiso Insulation Closed-cell PIR Foam Insulation Board 

ARDEX POLYISO flat board roofing insulation consists of a closed-cell polyiso foam core laminated to black glass reinforced mat facer on both surfaces. ARDEX POLYISO insulation provides outstanding thermal performance on commercial roofing applications.

All ARDEX POLYISO insulation boards incorporate a HCFC-free blowing agent that does not contribute to the depletion of the ozone (ODP-free).

The ARDEX POLYISO is suitable for adhered, ballasted and mechanically fastened single-ply roofing systems. It provides outstanding thermal resistance, dimensional and compressive strength. 

FEATURES and BENEFITS

  • Compatible with ballasted, fully adhered, and mechanically attached single-ply systems
  • Available in flat boards of 1.22m x 2.25m and in thicknesses ranging from 25.4mm to 101.6mm.
  • Provides outstanding thermal resistance, dimensional and compressive strength
  • Compatible with ARDEX recommended water based bonding adhesives
  • ARDEX TPO roofing systems installed over ARDEX POLYISO obtain BROOF(t1) fire rating  

R-values have been determined using the calculation method described in EN ISO 6946 standard based on the use of the ARDEX ISO 95+ insulation board waterproofed using a single-ply membrane and taking into account the surface resistances, both inside and outside.

If you require a more detailed R or U-value calculation, please contact the ARDEX Technical Department.  

Thickness (mm)

Thickness (inch)

R-Value (m2.K/W)

LTTR R-Value*

Flute Spanability (mm)

25.4mm

1.00

1.11

6.0

57.53mm

31.7mm

1.25

1.35

7

93.34mm

38.1mm

1.50

1.58

9.0

111.12mm

44.5mm

1.75

1.82

10.5

111.12mm

50.8mm

2.00

2.05

12.1

111.12mm

58.4mm

2.30

2.26

14.0

111.12mm

63.5mm

2.50

2.44

15.3

111.12mm

71.1mm

2.80

2.71

17.2

111.12mm

76.2mm

3.00

2.89

18.5

111.12mm

82.6mm

3.25

3.02

20.1

111.12mm

88.9mm

3.50

3.24

21.7

111.12mm

95.3mm

3.75

3.45

23.4

111.12mm

101.6mm

4.00

3.68

25.0

114.30mm

*Long Term Thermal Resistance (LTTR)  

Code Compliance

ARDEX POLYISO bears a variety of code body compliances noted below:

  • CE marked according to EN 13165
  • ASTM C-1289, Type II, Class 1
  • UL Classified
  • FM Class 1 Approved (insulated steel deck construction)
  • Manufactured in an ISO 9002 Registered Facility  

Packaging, storage and precautions

  1. Tuff-wrap packaging provides a durable protective covering to the top and four sides of the bundle, as well as a portion of the bottom board.
  2. Keep insulation dry at all times. Insulation bundles need to be elevated above the water line to prevent moisture infiltration from the bottom side.
  3. Combustible. Refer to MSDS for more information.
  4. Before insulation is placed on the roof deck, the substrate must be clean, dry, free of debris, water, ice or snow, and suitably prepared by removing all defects that might affect the quality of the application. Any unusual deck conditions or defects should be brought to the architect or building owner’s attention prior to installation.
  5. No more insulation shall be installed than can be covered with membrane and completed before the end of each day's work or before the onset of inclement weather.
  6. ARDEX POLYISO is non-structural, non-load-bearing material. The finished roof assembly should be protected from excessive roof traffic with proper walkway materials.  

Method of application

ARDEX POLYISO insulation boards must be installed using fasteners and plates, hot bitumen or ARDEX approved insulation adhesives. Insulation shall be neatly fitted to all roof perimeters, penetrations and abutments. The ARDEX POLYISO board is suitable for adhered, ballasted and mechanically fastened single-ply roofing systems.

Mechanical attached single-ply systems Fasten the insulation with a minimum of 5 approved fasteners and plates per 1.22m x 2.25m board. Additional fasteners may be required in areas of high wind loads or around the perimeter of the roof. Please refer to local wind uplift requirements and/or contact the ARDEX Technical Department.

Ballasted single-ply systems For ballasted systems, the top layer of ARDEX insulation may be loose laid or adhered. If mechanical attachment is specified, contact ARDEX Building Products for specific guidelines.  

Fully adhered single-ply systems Number of fasteners per board needs to be determined based on a wind uplift calculation in accordance with local building codes and taking into account the following minimum requirements:

  • Thicknesses less than 38.1 mm: Fasten insulation with minimum 16 fasteners per 1.22m x 2.25m board.
  • Thicknesses less than 50.8 mm: Fasten insulation with minimum 12 fasteners per 1.22m x 2.25m board.
  • Thicknesses less than 101.4 mm: Fasten insulation with minimum 8 fasteners per 1.22m x 2.25m board.  

Technical Properties  

Property

ASTM test

Typical Value

EN test

Typical Value

Density

D-1622

32 kg/m3

823

32 kg/m3

Compressive strength

D-1621

> 138 kPa

826

> 138 kPa

Dimensional stability

D-2126

< 2%

9.0

111.12mm

Water absorption

C-209

< 1% (by volume)

12087

<3% (by volume)

Service temperature     -73 oC to 121 oC

GUARANTEE

ARDEX Australia Pty Ltd (we or us) guarantees this product (our goods) is free from manufacturing defects and will perform to any applicable specification published by us for 10 years from the date of purchase. Our liability under this guarantee is limited at our option to replacement of the product, repair of any damage to the immediate surface or area of application of the product, or compensation, in each case if we are satisfied loss or damage was due to a breach of this guarantee. This guarantee does not apply if damage or loss is due to failure to follow published instructions or any act or circumstance beyond our control, including shade variations and efflorescence. If you wish to make a claim under this guarantee you must notify us (ARDEX Australia Pty Ltd, 20 Powers Road, Seven Hills NSW 2147; Toll Free: 1800 224 070 and provide evidence of your purchase of the product within 30 days of any alleged loss or damage occurring. We reserve the right to ask you for satisfactory evidence of any alleged loss or damage. Any claim under this guarantee is at your cost. This guarantee is in addition to any rights or remedies you may have as a consumer under the Australian Consumer Law and to that extent you need to be aware that: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss of damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.  

Disclaimer

The technical details, recommendations and other information contained in this data sheet are given in good faith and represent best of our knowledge and experience at the time of printing. It is your responsibility to ensure that our products are used and handled correctly and in accordance with any applicable Australian Standard, our instructions and recommendations are only for the uses they are intended. We also reserve the right to update information without prior notice to you to reflect our ongoing research and development program. Country specific recommendations, depending on local standards, codes of practice building regulations or industry guidelines may affect specific installation recommendations. The supply of our products and services is also subject to certain terms, warranties and exclusions, which may have already been disclosed to you in prior dealings or are otherwise available to you on request. You should make yourself familiar with them. ARDEX Australia Pty Ltd 2013. All aforementioned product

 

Waterproofing FAQ

Membrane Protection Board

Waterproofing Coating

Waterproof Drainage Sheet

Waterproofing Primer

Repair and Maintenance