Wrimco Waterproofing                              Home  | Specification | Product | Project | Technical data A-Z | Contact us

Adhesive Membrane

Anti-root Membrane

Approved Applicators

Backing Rod

Drainage Cell

Drainage Sheet

Epoxy Adhesive

Epoxy Flooring

Flat Roof Membrane  

Foundation Membrane

Liquid Membrane

Membrane Protection

Product Application

Product Category

Retaining Wall

SBS Sheet Membrane

Torch on Membrane

Under Slab Membrane

Vapour Barriers

Waterproofing Primer

 

Waterproof Balcony Liquid Membrane Waterproof Bathroom liquid membrane Waterproof Retaining Wall Liquid Rubber Membrane How to waterproof a bathroom Waterproof Internal Wet Area Membrane Waterproof Tiled Balcony Clear Penetrating Sealer Trafficable liquid membrane UV Protection Polyurethane Membrane Waterproof Water Feature liquid membrane Hydro Pressure Resistant liquid membrane Waterproof fish pond liquid membrane waterproof bathroom liquid membrane Waterproof above screed liquid membrane UV Resistant Polyurethane Membrane Waterproof leaking balcony liquid membrane waterproof damp basement wall liquid membrane Solutions to common waterproofing problems Maxseal Foundation Polyurethane Membrane MasterSeal M210TIX Latex Rubber Liquid Membrane Waterproof wet basement wall liquid membrane Injection Drill Pump Vulkem 350/345/346 Ardex WPM 300 Epoxy - Stop Rising Damp Waterproof Metal Roof Liquid Membrane Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer, waterproof Leaking Balcony, Flat Roof, Planter Box, Bathroom tradesman, handyman Waterproof Box gutter liquid membrane Waterproof Retaining Wall liquid membrane Waterproof Internal, External Wall Liquid Membrane Waterproof Concrete Slab Liquid Membrane Waterproof Balcony Liquid Membrane Stop Leaking Shower Liquid Membrane How to waterproof a retaining wall How to waterproof a Retaining Wall How to fix leaking fish pond Waterproof Garage Roof Liquid Rubber Membrane Waterproof water tanks for drinkable water Waterproof Leaking Roof, Gutters, Balcony, Car Park tradesman Waterproof leaking box gutters tradesman Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer   Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer   HiBuild Hydrastatic Water based Epoxy Hydrostatic Negative Pressure Water Based Epoxy Prevent and Fix Rising Damp Waterproofing Epoxy Waterproof exposed balcony liquid membrane Repair leaking Water Tank licensed Waterproofer Repair Leaking Fire Water Tank Licensed Contractors  Waterproofing Leaking Basement Licensed Water proofer Sikalastic 488 UV Trafficable Polyurethane Liquid Membrane SikaTite UnderTile Rapid
Commercial Building Sheet Membrane Concrete Roof Sheet Membrane Waterproof Deck Sheet Membrane Entertainment building Waterproofing Membrane Waterproof Government Building Sheet Membrane Waterproof Hospital Building Sheet Membrane Waterproof Landmark Building Bitumen Membrane Waterproofing Planter Box Sheet Membrane Waterproof Plywood Roof Sheet Membrane Waterproof Residential Building Sheet Membrane Waterproof Roof Bitumen Sheet Membrane Waterproof Flat Roof Sheet Membrane Waterproof Retaining Wall Sheet Membrane Terrace waterproofing Sheet Membrane Waterproof University Building Sheet Membrane Wrimco Reference Waterproof Lift Pit Sheet Membrane Waterproof Concrete Roof Sheet Membrane Tanking Sheet Membrane Systems Vaucluse Waterproofing Project  Mosman Waterproofing Project Waterproofing Palm Beach Waterproofing Dover Height Waterproofing Darling Point Waterproofing Bellevue Hill waterproofing tradesman Knowledge Base FAQ Waterproofing Product Waterproof Leaking Garage Roof tradesman Repair SBS, APP Sheet Membrane Waterproof Concrete Slab Sheet Membrane Waterproof Leaking Garage Roof Liquid Rubber Membrane Waterproof Leaking Metal Roof Liquid Rubber Membrane Waterproof Balustrade Sheet Membrane Waterproof Commercial Building Project Bitumen Sheet Membrane Closed Cell Backing Rod Repair Crack Joints Closed cell backer rod Expansion joint backing rod Backing Rod 20 Years Warranty 2 Layers Sheet Membrane System for Exposed Roof

DuroNon slip Coating   :

 
 
 
DuroNon Slip - External foot trafficable deck coating, is a modified DuroAC membrane with added fine grade aggregate to provide a Non-Slip, textured surface for decks and other exposed areas. Suitable for light foot traffic.
 

USE AREAS:   

 

Foot trafficable roof decks   

Balconies and decks with or without tiling

 
 
PRINCIPLE CHARACTERISTICS   

 

Single component   

Non-toxic, water clean up.   

Permanently flexible   

Seamless   

Environmentally Friendly   

UV stable   

Fungal and algae resistant   

Easily maintained   

Low odour   

 

General
 
2 hours @20  

Packaging   

15 litre   

 

PREPARATION   

 

All surfaces shall be sound, clean, dry and free of release curing agents and other contaminants. Check adhesion by applying to a test area. Concrete to be at least 28 days old, dry and free of voids and other surface defects. Make sure painted surfaces are sound and remove any chalking by pressure spray or light detergent wash. Roof decks should be properly drained for long-term serviceability of DuroNon Slip. A 12mm fillet of neutral cure silicone sealant is to be applied at all surface junctions.   

 
Concrete: Remove laitance or unsound concrete by water blast or mechanical means. Fill all porous or honeycombed concrete with appropriate and approved material.
Compressed Fibre cement sheets to be installed as per manufacturers specification and all joints to be sealed.
Movement cracks and cold joints to be cut out and filled with neutral cure silicone  sealant, then overlaid with DuroNon Slip reinforced with 140mm min.  wide bandage.   

 

Note: All sheet joints to have an expansion gap. Seal all surface joints and screw holes with neutral cure silicone sealant, and further seal joints and spread across a min. 20mm of the surface and overlay with tape and DuroNon Slip reinforced with 140mm (min.) wide bandage.   

 

PRIMING   

 

Prime surfaces with one or more coats of DuroWBE at a rate of 4-6 m2/ litre  (0.25-.017 litres/m2). Allow to dry 24 hours @ 25  C before overcoating with DuroNon Slip.   

 

APPLICATION
 

To the prepared surface, apply a first coat of DuroNon Slip by brush or roller at approximate rate of  1.0 litres/m2 per coat. Apply the second coat in the same direction to provide an even texture and finish. Check when dry and apply a further coat to give a total DFT of 1.2mm.   

 

PRECAUTIONS   

 

Do not apply above 30 C or below 10 C ambient temperature. Be sure coating is cured before contact with water. Wash equipment with water before dry. Do not fix tiles until fully cured, normally 1 - 4 days. Provide sufficient expansion and contraction control joints in overlaying tiling and topping. This is particularly important with FC sheet flooring.  Clean periodically to maintain surface and re-coat when necessary.    

 

CLEAN UP   

 

Use fresh water before material has set. Remove cured material with mineral turps.    

 

Waterproofing FAQ

Membrane Protection Board

Waterproofing Coating

Waterproof Drainage Sheet

Waterproofing Primer

Repair and Maintenance