Wrimco Waterproofing                              Home  | Specification | Product | Project | Technical data A-Z | Contact us

Adhesive Membrane

Anti-root Membrane

Approved Applicators

Backing Rod

Drainage Cell

Drainage Sheet

Epoxy Adhesive

Epoxy Flooring

Flat Roof Membrane  

Foundation Membrane

Liquid Membrane

Membrane Protection

Product Application

Product Category

Retaining Wall

SBS Sheet Membrane

Torch on Membrane

Under Slab Membrane

Vapour Barriers

Waterproofing Primer

 

Waterproof Balcony Liquid Membrane Waterproof Bathroom liquid membrane Waterproof Retaining Wall Liquid Rubber Membrane How to waterproof a bathroom Waterproof Internal Wet Area Membrane Waterproof Tiled Balcony Clear Penetrating Sealer Trafficable liquid membrane UV Protection liquid membrane Waterproof Water Feature liquid membrane Hydro Pressure Resistant liquid membrane Waterproof Shower Recess liquid membrane Repair Roof Gutters liquid Membrane Waterproof Planter Box liquid membrane Waterproof Under Tiles Liquid Membrane Waterproof Water Tanks liquid membrane waterproof Flat Roof liquid membrane Waterproof fish pond liquid membrane Waterproof Swimming Pool  How to stop tiled deck leaking waterproof bathroom liquid membrane Waterproof Leaking Shower Tradesman Waterproof Leaking Balcony Liquid Membrane Waterproof Damp Basement Wall Liquid Membrane Crystoflex Max Cementetious waterproofing membrane Waterproof Under Screed Liquid Membrane Waterproof above screed liquid membrane How to waterproof a Planter Box How to waterproof a shower How to waterproof tiled balcony Waterproof Roofs with UV liquid membrane How to waterproof a metal roof Sikalastic 560 - Repair Bitumen membrane Roof How to waterproof a planter box Waterproof Flat roof liquid membrane Below Grade Membrane UV Resistant Polyurethane Membrane Waterproof leaking balcony liquid membrane waterproof damp basement wall liquid membrane Solutions to common waterproofing problems Maxseal Foundation Mapelastic Smart Membrane Polyurethane Membrane MasterSeal M210TIX Latex Rubber Liquid Membrane Waterproof wet basement wall liquid membrane Waterproof leaking Basement Tradesman Waterproof Building Contractors Waterproof Lift Pit Contractors Waterproof leaking Internal Wall tradesman Waterproof leaking deck tradesman waterproof leaking roof, gutters, balcony, car park tradesman Waterproof leaking Box Gutter Tradesmen Waterproof leaking External Wall tradesmen Waterproof Swimming Pool Contractors Waterproof Garage Roof Liquid Membrane Injection Drill Pump Vulkem 350/345/346 Ardex WPM 300 Epoxy - Stop Rising Damp Ardex WPM300 Waterproof Metal Roof Liquid Membrane Waterproof Leaking Under Tiles Liquid Membrane Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer, waterproof Leaking Balcony, Flat Roof, Planter Box, Bathroom tradesman, handyman Waterproof exposed balcony liquid membrane Hydrostatic Pressure resistant Liquid Membrane Waterproof Box gutter liquid membrane Prevent Rising Damp Waterproofing Epoxy Waterproof leaking metal roof tradesman Waterproof Retaining Wall liquid membrane Waterproof Underground Walls liquid membrane Waterproof Internal, External Wall Liquid Membrane Waterproof Concrete Slab Liquid Membrane Waterproof Balcony Liquid Membrane Stop Leaking Shower Liquid Membrane How to repair a leaking fish pond Waterproof Wet Retaining Wall Liquid Membrane Waterproof Aluminium Roof Liquid Membrane How to waterproof a retaining wall How to waterproof a Retaining Wall Waterproof cement screed epoxy Vulkem 360NF Waterproof Car Park Liquid Membrane Waterproof Retaining Wall liquid membrane Waterproof Besser Block Wall Liquid Membrane How to fix leaking fish pond Waterproof Garage Roof Liquid Rubber Membrane Trafficable UV resistant liquid membrane Stop Basement Wall Leaking UV Resistant Polyurethane Liquid Membrane Waterproof water tanks for drinkable water Waterproof Commercial Roof, Balcony Contractors
Commercial Building Sheet Membrane Concrete Roof Sheet Membrane Waterproof Deck Sheet Membrane Entertainment building Waterproofing Membrane Waterproof Government Building Sheet Membrane Waterproof Hospital Building Sheet Membrane Waterproof Landmark Building Bitumen Membrane Waterproofing Planter Box Sheet Membrane Waterproof Plywood Roof Sheet Membrane Waterproof Residential Building Sheet Membrane Waterproof Roof Bitumen Sheet Membrane Waterproof Flat Roof Sheet Membrane Waterproof Retaining Wall Sheet Membrane Terrace waterproofing Sheet Membrane Waterproof University Building Sheet Membrane Wrimco Reference Waterproof Lift Pit Sheet Membrane Waterproof Car Park Roof Sheet Membrane Waterproof Concrete Slab Sheet Membrane Waterproof Concrete Roof Sheet Membrane Tanking Sheet Membrane Systems Vaucluse Waterproofing Project  Mosman Waterproofing Project Waterproofing Palm Beach Waterproofing Dover Height Waterproofing Darling Point Waterproofing Bellevue Hill waterproofing tradesman Under Concrete Slab Waterproofing Knowledge Base FAQ Waterproofing Product Waterproof Leaking Swimming pool tradesman Waterproof Leaking Garage Roof tradesman Repair SBS, APP Sheet Membrane Waterproof Concrete Slab Sheet Membrane Waterproof Leaking Garage Roof Liquid Rubber Membrane Waterproof Leaking Metal Roof Liquid Rubber Membrane Polyurethane Modified Acrylic Liquid Rubber Membrane Waterproof Balustrade Sheet Membrane Waterproof Commercial Building Project Bitumen Sheet Membrane Waterproofing Membrane Protection Drainage Cell Closed Cell Backing Rod Repair Crack Joints Closed cell backer rod Expansion joint backing rod Backing Rod waterproof leaking laundry tradesman Repair Leaking underground basement wall Waterproofer Waterproof leaking planter box tradesman Waterproof Leaking Shower Tradesman Waterproof Planter Box Tradesman Waterproof Leaking Box Gutter Tradesman Waterproof Leaking Balcony Tradesman Waterproof Leaking Fish Pond Tradesman Repair Construction Building Contractors

UV Resistant Polyurethane Liquid Membrane:  

   

Multithane 2P-A80 is a two part, elastomeric, heavy duty, trafficable, abrasion resistant, UV resistant, low VOC, polyurethane waterproofing membrane. Multithane 2P-A80 is formulated to provide a high tensile, puncture and tear resistant waterproofing membrane suitable for pedestrian and vehicular traffic. Multithane 2P-A80 is usually top coated with Multithane ATC A80 (aliphatic top coat), which is a tough, abrasion resistant, UV and colour stable top coat.

Uses:  

Multithane 2P-A80 is designed and formulated for use on:
Exposed roofs
Balconies, deck, podiums, terraces and concrete slabs.
Car park decks and ramps
Planters and landscape areas
Plant rooms and wash rooms
Laboratory and kitchen floors
Sports stadiums
Walk-ways, passage ways and pedestrian access areas.
Impact resistant internal flooring.
Note: For exposed areas, Multithane 2)-A80 must be top coated with Multithane ATC-A80.

Suitable Surfaces

Multithane 2P-A80 is suitable for use on most dry, sound and properly prepared and primed construction substrates such as:
Concrete and cementitious surfaces.
Block-work, brick-work and Hebel block.
Masonry
Timber

Note: Surfaces must be dry or have a low moisture content (max. 5%), clean, free of dirt, friable matter, oils, grease, concrete release and curing agents, efflorescence and other contaminants.
 

Specification

The information contained in this product data sheet is typical but does not constitute a full specification as conditions and specific requirements may vary from project to project. The instructions should be considered as a minimum requirement but the applicator or contractor must use their skill, knowledge and experience to carry out additional works as may be necessary to meet the requirements of the project. Specification for specific projects should be sought from the Company in writing.  

Limitations

Multithane 2P-A80 is a two part system and must be correctly mixed using the correct proportions. Deviations may result in a reduction in pot life or the product remaining partially uncured.

Benefits and Advantages

Multithane 2P-A80 is a highly technologically advanced polyurethane waterproofing membrane system and is:
Highly flexible 400% (meets CSIRO Class 111).
Low VOC meets Green star criteria.
Seamless
Fully bonded. Does not allow water to track between the substrate and the membrane.
Puncture and tear resistant.
Abrasion resistant.
Suitable for pedestrian and vehicular traffic.
Can be made non-slip.
Resistant to ponded water.
Chemically resistant
Tolerates a wide temperature range ( -30oC to 120oC)
Easy to apply

Precautions in Use

The product is not classifies as hazardous but good industrial practices and hygiene should be observed.
Impervious gloves, goggles (against splashes), coverall and boots should be worn.
Use in well ventilated areas. Avoid breathing in vapours.
Keep all sources of ignition away from uncured product.

Priming and Surface Preparation

Good preparation is essential. Surfaces must be sound, stable, dry, clean and free of dust, loose, flaking, friable material and substances that may diminish adhesion.  Surfaces must be sound, stable, dry, free of dirt, dust, friable material, grease, oils, release and curing agents and contaminants that may diminish adhesion.  Mirror finished or glassy smooth concrete should lightly abraded or acid treated (then neutralised), flushed and allowed to dry.  Prior coatings and membranes should be removed to provide a surface as described above.  Surface defects must be rectified.

Priming
Apply a coat of Primeseal SP at the rate of 7m2 to 8m2 per litre per coat. Highly porous areas may require an additional coat of primer. Green or damp concrete and where there is a risk of water vapour transmission from out of the substrate apply two coats of Primeseal SP at the rate of 7m2 to 8m2 per litre per coat. Allow each coat to dry (+/- 2 hours) before applying the next coat.

Important
Where detailed prepartion work is required, priming should be confined just to those areas. Do not prime areas that cannot be membraned within 2 hours (best) or 24 hours (maximum).
The membrane should be applied as soon as the final coat of primer is dry (± 2 hours from last priming coat) and within 24 hours.

Detailing Preparation

Corners
Prime as required.
Apply an adequate flexible polyurethane sealant, in accordance the manufacture's instruction and tool off to form a solid, coved or 45 degree fillet extending at least 10mm on to the adjacent surfaces. Allow sealant to cure. Apply the Duram membrane directly over the cured sealant and on the adjacent surfaces.
Joins, Gaps and Cracks

General
Joins, gaps and cracks should be suitably filled and sealed with an appropriate elastomeric sealant, preferably a polyurethane sealant, and allowed to cure. 
Recommendation: The movement of small cracks should not be underestimated and should be at least covered with a flexible polyurethane sealant or additional coats of membrane.  Where movement of the joint is expected, lay a bond breaker tape over the filled crack and apply a 150mm wide good coat of Multithane Std over the crack and then embed a suitable reinforcing fabric into the wet coat, followed by a saturating coat of Multithane Std. Allow to cure and apply a further coat of Multithane Std. The dry film thickness over these cracks should be at least 2mm.

Large or Live Cracks
Large cracks should be routed out to form a 'V' and then filled and sealed with a polyurethane waterproof joint sealant as per the manufacturer's instructions. The sealant should be finished slightly proud of the surface and allowed to cure. 
Lay a bond breaker tape over the filled crack and apply a 150mm wide good coat of Multithane Std over the crack and then embed a suitable reinforcing fabric into the wet coat, followed by a saturating coat of Multithane Std. Allow to cure and apply a further coat of Multithane Std. The dry film thickness over these cracks should be at least 2mm.
 

Joins - Particularly in CFC Sheeting and Timber Sheeting
Ideally the sides of the sheets should be fully coated with a flexible polyurethane waterproof joint sealant prior to butting the sheets together.
If not, the joins should be suitably filled and sealed with an appropriate elastomeric, construction grade, polyurethane waterproof sealant and finished flush with or preferably slightly proud of the surface and allowed to cure. 
After priming as required, lay a strip of Leak-Seal Tape over the join, pressing it firmly on to the substrate. The membrane is then as described under 'Large or Live Cracks'.
If the Leak-Seal is not used then follow the procedure as described under 'Large or Live Cracks'.

Waste Outlets, Penetrations and Angles
Waste Outlets: Floor wastes and puddle flanges should be rebated in to the floor to allow water to readily drain. Gaps and perimeters should be sealed with a polyurethane sealant.
Plastic or metal angles: Where required by the Building Code such as internal hobs and exterior door barriers and also plastic corner angels under wall boards, they should be securely embedded in to a continuous, gap free bed of a polyurethane sealant / mastic.

Application

Product Preparation:
Given the pot life of the material, have all components ready. Before use, mix individual pails separately (avoiding aeration) with a clean and dry stirrer ensuring that there is no cross contamination between Parts A and Parts B.
It is recommended that the product be used in complete kits as supplied. If not, measure by weight strictly in the ratio of 23.1 grams of Hardener with 100 grams of Resin. 
Measure individual Parts A and Parts B components accurately in required proportion in to a separate clean and dry container and mix thoroughly with a mechanical stirrer (avoiding aeration) periodically  scraping the bottom and sides of the container. Ideally, use the products in complete kits as supplied.

Application.  Apply to notched trowel, roller or brush as follows:

Non-Exposed Membrane System
Apply two coats of Multithane 2P-A80 at the minimum  rate of 1kg per m2 per coat allowing each coat to cure before applying the next. Following coats, including Multithane ATC-A80, must be applied as soon as the preceding coat is dry and within 24 hours to maximum of 48 hours. The minimum dry film thickness of the cured membrane must be 1.5mm.
 
Exposed Membrane System
Apply a coat of Multithane ATC-A80 to cured membrane at the rate of 3m2 per litre within 24 hours  to maximum of 48 hours of applying the Multithane 2P-A80 membrane. The dry film thickness must be at least 0.3mm.
The overall combined dry film thickness must be at least 1.75mm to 2.0mm.

Non-Exposed Anti-Slip Membrane System
Apply a coats of Multithane 2P-A80 at the minimum  rate of 1.5kg to 1.75kg per m².  Allowing to cure. As soon as the preceding coat is dry and within 24 hours to a maximum of 48 hours apply a second coat of Multithane 2P-A80 at the rate of 0.5kg per m2 and while wet, broadcast the anti-slip grit to excess. Allow the membrane to cure and then remove loose grit.  The minimum dry film thickness of the cured membrane must be 2.0mm. 

Exposed Anti-Slip Membrane System
Apply a coats of Multithane 2P-A80 at the minimum  rate of 1.5kg to 1.75kg per m2.  Allowing to cure. As soon as the preceding coat is dry and within 24 hours to a maximum of 48 hours apply a second coat of Multithane 2P-A80 at the rate of 0.5kg per m2 and while wet, broadcast the anti-slip grit to excess. Allow the membrane to cure and then remove loose grit.  The minimum dry film thickness of the cured membrane must be 2.0mm. 
Apply a coat of Multithane ATC-A80 to cured membrane at the rate of 3m2 per litre. The dry film thickness must be at least 0.3mm.

Important:
Pot Life: Depending upon ambient temperature and quantity of product mixed, the pot life of the mixed product is 20 to 30 minutes. Once thickened or set, the product is unusable and must not be thinned using solvents in an attempt to prolong the pot life or reconstitute the product.

Coverage

The stated average coverage rate may vary depending upon type, condition, porosity, texture of the surface and application technique.  

Standard Membrane
Multithane 2P-A80: 1kg per m2 per coat. Minimum dry film thickness - 1.5mm
Multithane ATC-A80: 0.5kg per m2. Minimum dry film thickness - 0.3mm.

Anti-Slip Membrane
Multithane 2P-A80: 2kg per m2 finished. Minimum dry film thickness - 2.0mm
Multithane ATC-A80: 0.5kg per m2. Minimum dry film thickness - 0.3mm.

Packaging

Primer: Duram Primeseal SP- 4 litre and 15 litre pails
Membrane: Multithane 2P-A80 in 20kg kits
Top Coat: Multithane ATC-A80 in 15 litre pails

Colours

Usually supplied in grey, but can be supplied in other colours. Minimum quantities may apply.  Tiling, Topping or Top Coating

For functional or aesthetic reasons the membrane may be covered or topped.
Tiling:
Tiles may be laid in to a mortar bed or directly bonded.
Landscaping: 
Protect the membrane with a suitable protection board or drainage cell.
For additional anti-root resistance apply two coats of Rocktuff to the cured membrane with 24 hours after applying the membrane.
Rigid Toppings
Lay a suitable protection board or 0.2mm plastic slip sheet over the membrane.

Protect membrane from point loads and pavers should be supported on appropriate pads

 