Wrimco Waterproofing                              Home  | Specification | Product | Project | Technical data A-Z | Contact us

Adhesive Membrane

Anti-root Membrane

Approved Applicators

Backing Rod

Drainage Cell

Drainage Sheet

Epoxy Adhesive

Epoxy Flooring

Flat Roof Membrane  

Foundation Membrane

Liquid Membrane

Membrane Protection

Product Application

Product Category

Retaining Wall

SBS Sheet Membrane

Torch on Membrane

Under Slab Membrane

Vapour Barriers

Waterproofing Primer

 

Waterproof Balcony Liquid Membrane Waterproof Bathroom liquid membrane Waterproof Retaining Wall Liquid Rubber Membrane How to waterproof a bathroom Waterproof Internal Wet Area Membrane Waterproof Tiled Balcony Clear Penetrating Sealer Trafficable liquid membrane UV Protection liquid membrane Waterproof Water Feature liquid membrane Hydro Pressure Resistant liquid membrane Waterproof fish pond liquid membrane waterproof bathroom liquid membrane Waterproof above screed liquid membrane UV Resistant Polyurethane Membrane Waterproof leaking balcony liquid membrane waterproof damp basement wall liquid membrane Solutions to common waterproofing problems Maxseal Foundation Polyurethane Membrane MasterSeal M210TIX Latex Rubber Liquid Membrane Waterproof wet basement wall liquid membrane Injection Drill Pump Vulkem 350/345/346 Ardex WPM 300 Epoxy - Stop Rising Damp Waterproof Metal Roof Liquid Membrane Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer, waterproof Leaking Balcony, Flat Roof, Planter Box, Bathroom tradesman, handyman Waterproof Box gutter liquid membrane Waterproof Retaining Wall liquid membrane Waterproof Internal, External Wall Liquid Membrane Waterproof Concrete Slab Liquid Membrane Waterproof Balcony Liquid Membrane Stop Leaking Shower Liquid Membrane How to waterproof a retaining wall How to waterproof a Retaining Wall How to fix leaking fish pond Waterproof Garage Roof Liquid Rubber Membrane Waterproof water tanks for drinkable water Waterproof Leaking Roof, Gutters, Balcony, Car Park tradesman Waterproof leaking box gutters tradesman Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer   Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer   HiBuild Hydrastatic Water based Epoxy Hydrostatic Negative Pressure Water Based Epoxy Under tile screed bed waterproofing membrane Prevent and Fix Rising Damp Waterproofing Epoxy Waterproof exposed balcony liquid membrane Repair leaking balcony waterproof liquid membrane Waterproof Bathroom Liquid Membrane Planter Box Retaining Wall Tanking Liquid Membrane Waterproof Leaking Metal Roof Waterproofer HOw to repair leaking fish pond Waterproof Underground wall Liquid Membrane Waterproof Planter Box liquid membrane Waterproof Watertanks Cementitious Liquid Membrane Waterproof Lift Pit Liquid Membrane ARDEX WPM 001 - Undertile Waterproofing Membrane Waterproof Planter Box Root Resistant Liquid Membrane Repair Bitumen Roof Waterproofing Liquid Membrane UV Protective Polyurethane Membrane Waterproof External Brick Wall liquid membrane Waterproof Retaining Wall Liquid Membrane Waterproof Planter Box Liquid Membrane Waterproof Wet Retaining Wall Liquid Membrane Waterproof Leaking External Wall Licensed Waterproofer Emer Clad Acrylic Liquid Membrane Waterproof Planter Box, Retaining wall liquid membrane Fast Cure Elastomeric Waterproofing Membrane Systems Waterproof Leaking Swimming pool tradesman UV Resistant Acrylic Liquid Membrane How to Waterproof a Leaking Metal Box Gutter Sikalastic 560 - Repair Bitumen membrane Roof Waterproof Lift Pits Tradesmen Waterproof Leaking Kitchen Tradesmen Waterproof Leaking Internal Basement Walls tradesman Waterproof Leaking Laundry tradesman Waterproof Leaking Deck, Verandah Tradesman Waterproof Leaking Roof, Gutters, Balcony, Car Park Tradesman Repair Bitumen Roof Liquid Rubber Membrane Waterproof Besser Block Wall with Liquid Membrane Waterproof leaking bitumen roof contractors Waterproof leaking bitumen roof contractors  Waterproof Leaking Retaining Wall, Basement Wall Tradesmen
Commercial Building Sheet Membrane Concrete Roof Sheet Membrane Waterproof Deck Sheet Membrane Entertainment building Waterproofing Membrane Waterproof Government Building Sheet Membrane Waterproof Hospital Building Sheet Membrane Waterproof Landmark Building Bitumen Membrane Waterproofing Planter Box Sheet Membrane Waterproof Plywood Roof Sheet Membrane Waterproof Residential Building Sheet Membrane Waterproof Roof Bitumen Sheet Membrane Waterproof Flat Roof Sheet Membrane Waterproof Retaining Wall Sheet Membrane Terrace waterproofing Sheet Membrane Waterproof University Building Sheet Membrane Wrimco Reference Waterproof Lift Pit Sheet Membrane Waterproof Concrete Roof Sheet Membrane Tanking Sheet Membrane Systems Vaucluse Waterproofing Project  Mosman Waterproofing Project Waterproofing Palm Beach Waterproofing Dover Height Waterproofing Darling Point Waterproofing Bellevue Hill waterproofing tradesman Knowledge Base FAQ Waterproofing Product Waterproof Leaking Garage Roof tradesman Repair SBS, APP Sheet Membrane Waterproof Concrete Slab Sheet Membrane Waterproof Leaking Garage Roof Liquid Rubber Membrane Waterproof Leaking Metal Roof Liquid Rubber Membrane Waterproof Balustrade Sheet Membrane Waterproof Commercial Building Project Bitumen Sheet Membrane Closed Cell Backing Rod Repair Crack Joints Closed cell backer rod Expansion joint backing rod Backing Rod Waterproof Leaking Roof, Balcony, Box Gutter tradesman Repair Leaking underground basement wall Waterproofer Waterproof Leaking Shower, Bathroom, Wet area Tradesman Repair Leaking Deck, Planter Box Waterproofer Waterproof Leaking Fish Pond Tradesman Waterproof Rising Damp Basement Tradesmen Roofs Waterproofed with Wrimco Sheet Membrane Waterproof Retaining walls with sheet membrane Waterproof Balcony with Sheet Membrane HDPE Self Adhesive Sheet Membrane Waterproof Commercial High Rise Building Roof Contractors Waterproof Car Park Roof with sheet membrane Ardex WPM 116 Sheet Membrane Ardex WPM 150 APP Sheet Membrane ARDEX WPM 188 Garden Tanking Membrane ARDEX WPM 185 APP Sheet Membrane Ardex WPM320 Retaining Wall Sheet Membrane Waterproof Deck with torch applied Sheet Membrane ARDEX WPM612 FL TPO Fleece-Backed Roof Membrane TREMproof SBS 4000M Mineral Bituminous Membrane ARDEX WPM 1000 Weldable Waterproofing Membrane SBS Sheet Membrane Installation ARDEX WPM 3000X peel and stick membrane ARDEX WPM 750 Undertile Butynol  Waterproof Concrete Slab with Sheet Membrane ARDEX WPM 444 APP Sheet Membrane How to waterproof a Retaining wall How to waterproof a Planter Box How to waterproof a planter box How to waterproof Tiled Balcony with clear sealer How to waterproof a Shower  Ardex SRO 834 Waterproofing Specification Wrimco Sheet Membrane Waterproof elevator pits Sheet Membrane SBS Sheet Waterproofing Membrane How to waterproof balcony with sheet membrane Anti Root Sheet Membrane Vehicular Traffic Liquid Membrane Waterproof Planter Box with torch applied sheet membrane Waterproof Balconies Decks Podiums Prevent Rising Damp Hydro Static Epoxy How to waterproof a planter box 

Vehicular Traffic Liquid Membrane:   

   

Multithane 2P-A80 is a two part, elastomeric, heavy duty, trafficable, abrasion reistant, uv resistant, low VOC, polyurethane waterproofing membrane. Multithane 2P-A80 is formulated to provide a high tensile, puncture and tear resistant waterproofing membrane suitable for pedestrian and vehicular traffic. Multithane 2P-A80 is usually top coated with Multithane ATC A80 (aliphatic top coat), which is a tough, abrasion resistant, uv and colour stable top coat.

 

Uses

 

Multithane 2P-A80 is designed and formulated for use on:

 

Exposed roofs
Balconies, deck, podiums, terraces and concrete slabs.
Car park decks and ramps
Planters and landscape areas
Plant rooms and wash rooms
Laboratory and kitchen floors
Sports stadiums
Walk-ways, passage ways and pedestrian access areas.
Impact resistant internal flooring.

Note: For exposed areas, Multithane 2)-A80 must be top coated with Multithane ATC-A80.

 

Suitable Surfaces

 

Multithane 2P-A80 is suitable for use on most dry, sound and properly prepared and primed construction substrates such as:
Concrete and cementitious surfaces.
Block-work, brick-work and Hebel block.
Masonry
Timber
Note: Surfaces must be dry or have a low moisture content (max. 5%), clean, free of dirt, friable matter, oils, grease, concrete release and curing agents, efflorescence and other contaminants.

 

Specification

 

The information contained in this product data sheet is typical but does not constitute a full specification as conditions and specific requirements may vary from project to project. The instructions should be considered as a minimum requirement but the applicator or contractor must use their skill, knowledge and experience to carry out additional works as may be necessary to meet the requirements of the project. Specification for specific projects should be sought from the Company in writing.

 

Limitations

 

Multithane 2P-A80 is a two part system and must be correctly mixed using the correct proportions. Deviations may result in a reduction in pot life or the product remaining partially uncured.

Benefits and Advantages

 

Multithane 2P-A80 is a highly technologically advanced polyurethane waterproofing membrane system and is:


Highly flexible:  + 400% (meets CSIRO Class 111).
Low VOC: meets Green star criteria.
Seamless
Fully bonded. Does not allow water to track between the substrate and the membrane.
Puncture and tear resistant.
Abrasion resistant.
Suitable for pedestrian and vehicular traffic.
Can be made non-slip.
Resistant to ponded water.
Chemically resistant
Tolerates a wide temperature range ( -30 C to 120 C)
Easy to apply


Precautions in Use

 

The product is not classifies as hazardous but good industrial practises and hygiene should be observed.
Impervious gloves, goggles (against splashes), coverall and boots should be worn.
Use in well ventilated areas. Avoid breathing in vapours.
Keep all sources of ignition away from uncured product.

Priming and Surface Preparation

Good preparation is essential. Surfaces must be sound, stable, dry, clean and free of dust, loose, flaking, friable material and substances that may diminish adhesion.

 

Surfaces must be sound, stable, dry, free of dirt, dust, friable material, grease, oils, release and curing agents and contaminants that may diminish adhesion. Mirror finished or glassy smooth concrete should lightly abraded or acid treated (then neutralised), flushed and allowed to dry. Prior coatings and membranes should be removed to provide a surface as described above.

Surface defects must be rectified.

Priming


Apply a coat of Primeseal SP at the rate of 7 sqm to 8 sqm per litre per coat. Highly porous areas may require an additional coat of primer.

Green or damp concrete and where there is a risk of water vapour transmission from out of the substrate apply two coats of Primeseal SP at the rate of 7 sqm to 8 sqm per litre per coat. Allow each coat to dry (2 hours) before applying the next coat.

Important


Where detailed preparation work is required, priming should be confined just to those areas. Do not prime areas that cannot be membraned within 2 hours (best) or 24 hours (maximum). The membrane should be applied as soon as the final coat of primer is dry (2 hours from last priming coat) and within 24 hours.


Detailing Preparation

Corners


Prime as required.
Apply an adequate flexible polyurethane sealant such as Resiflex FC33, in accordance the manufacture's instruction and tool off to form a solid, coved or 45 degree fillet extending at least 10mm on to the adjacent surfaces. Allow sealant to cure. Apply the liquid membrane directly over the cured sealant and on the adjacent surfaces.


Joins, Gaps and Cracks
General


Joins, gaps and cracks should be suitably filled and sealed with an appropriate elastomeric sealant, preferably a polyurethane sealant such as Resiflex FC33, and allowed to cure.


Recommendation: The movement of small cracks should not be underestimated and should be at least covered with a flexible polyurethane sealant or additional coats of membrane.
Where movement of the joint is expected, lay a bond breaker tape over the filled crack and apply a 150mm wide good coat of Multithane Std over the crack and then embed a suitable reinforcing fabric into the wet coat, followed by a saturating coat of Multithane Std. Allow to cure and apply a further coat of Multithane Std. The dry film thickness over these cracks should be at least 2mm.


Large or Live Cracks


Large cracks should be routed out to form a 'V' and then filled and sealed with a polyurethane waterproof joint sealant as per the manufacturer's instructions. The sealant should be finished slightly proud of the surface and allowed to cure. 
Lay a bond breaker tape over the filled crack and apply a 150mm wide good coat of Multithane Std over the crack and then embed a suitable reinforcing fabric into the wet coat, followed by a saturating coat of Multithane Std. Allow to cure and apply a further coat of Multithane Std. The dry film thickness over these cracks should be at least 2mm.

 

Joins - Particularly in CFC Sheeting and Timber Sheeting


Ideally the sides of the sheets should be fully coated with a flexible polyurethane waterproof joint sealant prior to butting the sheets together.
If not, the joins should be suitably filled and sealed with an appropriate elastomeric, construction grade, polyurethane waterproof sealant such as Resiflex FC33 and finished flush with or preferably slightly proud of the surface and allowed to cure. 
After priming as required, lay a strip of Leak-Seal Tape over the join, pressing it firmly on to the substrate. The liquid membrane is then as described under 'Large or Live Cracks'.
If the Leak-Seal is not used then follow the procedure as described under 'Large or Live Cracks'.

Waste Outlets, Penetrations and Angles
Waste Outlets: Floor wastes and puddle flanges should be rebated in to the floor to allow water to readily drain. Gaps and perimeters should be sealed with a polyurethane sealant.
Plastic or metal angles: Where required by the Building Code such as internal hobs and exterior door barriers and also plastic corner angels under wall boards, they should be securely embedded in to a continuous, gap free bed of a polyurethane sealant / mastic.

 

Application

Product Preparation:


Given the pot life of the material, have all components ready. Before use, mix individual pails separately (avoiding aeration) with a clean and dry stirrer ensuring that there is no cross contamination between Parts A and Parts B.
Measure individual Parts A and Parts B components accurately in required proportion in to a separate clean and dry container and mix thoroughly with a machine stirrer (avoiding aeration) periodically scraping the bottom and sides of the container. Ideally, use the products in complete kits as supplied.

Application
Apply to notched trowel, roller or brush as follows:

Non-Exposed Membrane System


Apply two coats of Multithane 2P-A80 at the minimum  rate of 1kg per sqm per coat allowing each coat to cure before applying the next. Following coats, including Multithane ATC-A80, must be applied as soon as the preceding coat is dry and within 24 hours to maximum of 48 hours. The minimum dry film thickness of the cured membrane must be 1.5mm.
 
Exposed Membrane System


Apply a coat of Multithane ATC-A80 to cured membrane at the rate of 3 sqm per litre within 24 hours  to maximum of 48 hours of applying the Multithane 2P-A80 membrane. The dry film thickness must be at least 0.3mm.
The overall combined dry film thickness must be at least 1.75mm to 2.0mm.

Non-Exposed Anti-Slip Membrane System


Apply a coats of Multithane 2P-A80 at the minimum  rate of 1.5kg to 1.75kg per sqm.  Allowing to cure. As soon as the preceding coat is dry and within 24 hours to a maximum of 48 hours apply a second coat of Multithane 2P-A80 at the rate of 0.5kg per sqm and while wet, broadcast the anti-slip grit to excess. Allow the membrane to cure and then remove loose grit.  The minimum dry film thickness of the cured membrane must be 2.0mm. 

Exposed Anti-Slip Membrane System


Apply a coats of Multithane 2P-A80 at the minimum  rate of 1.5kg to 1.75kg per sqm  Allowing to cure. As soon as the preceding coat is dry and within 24 hours to a maximum of 48 hours apply a second coat of Multithane 2P-A80 at the rate of 0.5kg per m² and while wet, broadcast the anti-slip grit to excess. Allow the membrane to cure and then remove loose grit.  The minimum dry film thickness of the cured membrane must be 2.0mm. 
Apply a coat of Multithane ATC-A80 to cured membrane at the rate of 3 sqm per litre. The dry film thickness must be at least 0.3mm.

Important:


Pot Life: Depending upon ambient temperature and quantity of product mixed, the pot life of the mixed product is 20 to 30 minutes. Once thickened or set, the product is unusable and must not be thinned using solvents in an attempt to prolong the pot life or reconstitute the product.

Coverage

 

The stated average coverage rate may vary depending upon type, condition, porosity, texture of the surface and application technique.

 

Standard Membrane


Multithane 2P-A80:   1kg per sqm per coat. Minimum dry film thickness - 1.5mm
Multithane ATC-A80: 0.5kg per sqm.  Minimum dry film thickness - 0.3mm.

Anti-Slip Membrane


Multithane 2P-A80:   2kg per sqm finished. Minimum dry film thickness - 2.0mm
Multithane ATC-A80: 0.5kg per sqm.  Minimum dry film thickness - 0.3mm.

Packaging

Primer:        Primeseal SP- 4 litre and 15 litre pails
Membrane: Multithane 2P-A80    in 20kg kits
Top Coat:   Multithane ATC-A80 in 15 litre pails

Colours

 

Usually supplied in grey, but can be supplied in other colours. Minimum quantities may apply.

 

Tiling, Topping or Top Coating

For functional or aesthetic reasons the membrane may be covered or topped.

Tiling:
Tiles may be laid in to a mortar bed or directly bonded.


Landscaping: 
Protect the membrane with a suitable protection board or drainage cell.
For additional anti-root resistance apply two coats of Rocktuff to the cured membrane with 24 hours after applying the membrane.


Rigid Toppings
Lay a suitable protection board or 0.2mm plastic slip sheet over the membrane.
Protect membrane from point loads and pavers should be supported on appropriate pads.

 