Wrimco Waterproofing                              Home  | Specification | Product | Project | Technical data A-Z | Contact us

Adhesive Membrane

Anti-root Membrane

Approved Applicators

Backing Rod

Drainage Cell

Drainage Sheet

Epoxy Adhesive

Epoxy Flooring

Flat Roof Membrane  

Foundation Membrane

Liquid Membrane

Membrane Protection

Product Application

Product Category

Retaining Wall

SBS Sheet Membrane

Torch on Membrane

Under Slab Membrane

Vapour Barriers

Waterproofing Primer

 

Waterproof Balcony Liquid Membrane Waterproof Bathroom liquid membrane Waterproof Retaining Wall Liquid Rubber Membrane How to waterproof a bathroom Waterproof Internal Wet Area Membrane Waterproof Tiled Balcony Clear Penetrating Sealer Trafficable liquid membrane UV Protection liquid membrane Waterproof Water Feature liquid membrane Hydro Pressure Resistant liquid membrane Waterproof Shower Recess liquid membrane Repair Roof Gutters liquid Membrane Waterproof Planter Box liquid membrane Waterproof Under Tiles Liquid Membrane Waterproof Water Tanks liquid membrane waterproof Flat Roof liquid membrane Waterproof fish pond liquid membrane Waterproof Swimming Pool  How to stop tiled deck leaking waterproof bathroom liquid membrane Waterproof Leaking Shower Tradesman Waterproof Leaking Balcony Liquid Membrane Waterproof Damp Basement Wall Liquid Membrane Crystoflex Max Cementetious waterproofing membrane Waterproof Under Screed Liquid Membrane Waterproof above screed liquid membrane How to waterproof a Planter Box How to waterproof a shower How to waterproof tiled balcony Waterproof Roofs with UV liquid membrane How to waterproof a metal roof Sikalastic 560 - Repair Bitumen membrane Roof How to waterproof a planter box Waterproof Flat roof liquid membrane Below Grade Membrane UV Resistant Polyurethane Membrane Waterproof leaking balcony liquid membrane waterproof damp basement wall liquid membrane Solutions to common waterproofing problems Maxseal Foundation Mapelastic Smart Membrane Polyurethane Membrane MasterSeal M210TIX Latex Rubber Liquid Membrane Waterproof wet basement wall liquid membrane Waterproof leaking Basement Tradesman Waterproof Building Contractors Waterproof Lift Pit Contractors Waterproof leaking Internal Wall tradesman Waterproof leaking deck tradesman waterproof leaking roof, gutters, balcony, car park tradesman Waterproof leaking Box Gutter Tradesmen Waterproof leaking External Wall tradesmen Waterproof Swimming Pool Contractors Waterproof Garage Roof Liquid Membrane Injection Drill Pump Vulkem 350/345/346 Ardex WPM 300 Epoxy - Stop Rising Damp Ardex WPM300 Waterproof Metal Roof Liquid Membrane Waterproof Leaking Under Tiles Liquid Membrane Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer, waterproof Leaking Balcony, Flat Roof, Planter Box, Bathroom tradesman, handyman Waterproof exposed balcony liquid membrane Hydrostatic Pressure resistant Liquid Membrane Waterproof Box gutter liquid membrane Prevent Rising Damp Waterproofing Epoxy Waterproof leaking metal roof tradesman Waterproof Retaining Wall liquid membrane Waterproof Underground Walls liquid membrane Waterproof Internal, External Wall Liquid Membrane Waterproof Concrete Slab Liquid Membrane Waterproof Balcony Liquid Membrane Stop Leaking Shower Liquid Membrane How to repair a leaking fish pond Waterproof Wet Retaining Wall Liquid Membrane Waterproof Aluminium Roof Liquid Membrane How to waterproof a retaining wall How to waterproof a Retaining Wall Waterproof cement screed epoxy Vulkem 360NF Waterproof Car Park Liquid Membrane Waterproof Retaining Wall liquid membrane Waterproof Besser Block Wall Liquid Membrane How to fix leaking fish pond Waterproof Garage Roof Liquid Rubber Membrane Trafficable UV resistant liquid membrane Stop Basement Wall Leaking UV Resistant Polyurethane Liquid Membrane Waterproof water tanks for drinkable water
Commercial Building Sheet Membrane Concrete Roof Sheet Membrane Waterproof Deck Sheet Membrane Entertainment building Waterproofing Membrane Waterproof Government Building Sheet Membrane Waterproof Hospital Building Sheet Membrane Waterproof Landmark Building Bitumen Membrane Waterproofing Planter Box Sheet Membrane Waterproof Plywood Roof Sheet Membrane Waterproof Residential Building Sheet Membrane Waterproof Roof Bitumen Sheet Membrane Waterproof Flat Roof Sheet Membrane Waterproof Retaining Wall Sheet Membrane Terrace waterproofing Sheet Membrane Waterproof University Building Sheet Membrane Wrimco Reference Waterproof Lift Pit Sheet Membrane Waterproof Car Park Roof Sheet Membrane Waterproof Concrete Slab Sheet Membrane Waterproof Concrete Roof Sheet Membrane Tanking Sheet Membrane Systems Vaucluse Waterproofing Project  Mosman Waterproofing Project Waterproofing Palm Beach Waterproofing Dover Height Waterproofing Darling Point Waterproofing Bellevue Hill waterproofing tradesman Under Concrete Slab Waterproofing Knowledge Base FAQ Waterproofing Product Waterproof Leaking Swimming pool tradesman Waterproof Leaking Garage Roof tradesman Repair SBS, APP Sheet Membrane Waterproof Concrete Slab Sheet Membrane Waterproof Leaking Garage Roof Liquid Rubber Membrane Waterproof Leaking Metal Roof Liquid Rubber Membrane Polyurethane Modified Acrylic Liquid Rubber Membrane Waterproof Balustrade Sheet Membrane Waterproof Commercial Building Project Bitumen Sheet Membrane Waterproofing Membrane Protection Drainage Cell Closed Cell Backing Rod Repair Crack Joints Closed cell backer rod Expansion joint backing rod Backing Rod waterproof leaking laundry tradesman Repair Leaking underground basement wall Waterproofer Waterproof leaking planter box tradesman Waterproof Leaking Shower Tradesman Waterproof Planter Box Tradesman Waterproof Box Gutter Tradesman

Fast Curing Polyurethane Joint Sealant:  

Dymonic FC is a low-modulus, one-component, moisture-cure, polyurethane hybrid sealant. Dymonic FC is formulated with proprietary silane end-capped polymer technology. Dymonic FC provides the best performance characteristics of polyurethane and silicone sealants.

 

Basic Uses

 

Dymonic FC is a durable, flexible, sealant that offers excellent performance in moving joints and exhibits tenacious adhesion once fully cured. Typical applications for Dymonic FC include expansion and control joints, precast concrete panel joints, perimeter caulking (windows, door, panels), EIFS, aluminum, masonry and vinyl siding.

 

Features and Benefits

 

Dymonic FC is fast curing with a skin time of 60 minutes and a tack-free time of 3-4 hours to significantly reduce dirt pickup. It will not green crack due to early movement and has an exceptional movement capability of +/-35%. Dymonic FC is

also low-VOC, paintable and will not crack or craze under UV exposure.

 

Colors

 

Almond, Beige, Black, Anodized Aluminum, Aluminum Stone, Buff, Dark Bronze, Grey, Limestone, Off White, Redwood Tan, Stone, White, Natural Clay, Bronze and Ivory.

 

Packaging

 

10.1 oz (300 mL) cartridges; 20 oz (600 mL) sausages; 2 gal (7.6 L), 3 gal (11.4 L) and 5 gal (19 L) pails.

 

Coverage Rates

 

308 linear feet of joint per gallon for a 1/4 in. x 1/4 in. (6 mm x 6 mm) joint. For specific coverage rates that include joint size and usage efficiencies.

 

Applicable Standards

 

Dymonic FC meets or exceeds the requirements of the following specifications:

ASTM C920 Type S, Grade NS, Class 35, Use NT, M, A and O

ASTM C1248

U.S. Federal Specification TT-S-00230C Class A, Type II

CAN/CGSB 19.13-M87

Fire-Rated Systems

FF-D-1063, FW-D-1059, HW-D-1054, WW-D-1054

 

Joint Design

 

Dymonic FC may be used in any joint designed in accordance with accepted architectural/engineering practices. Joint width should be 4 times anticipated movement, but not less than 1/4 in. (6 mm).

 

Joint Backing

 

Closed cell or reticulated polyethylene backer rod is recommended as joint backing to control sealant depth and to ensure intimate contact of sealant with joint walls when tooling. Where depth of joint will prevent the use of backer

rod, an adhesive backed polyethylene tape (bond breaker tape) should be used to prevent three-sided adhesion. All backing should be dry at time of sealant application.

 

Typical physical properties

 

Property

Test Method

Typical Value

Rheological Properties

ASTM C639

Non-sag (NS), 0"of sag in channel

Extrusion Rate

ASTM C1183

93.1 ml/min

Hardness Properties

ASTM C661

25

Weight Loss

ASTM C1246

Pass

Skin Time

 

1 hr

Tack Free Time

ASTM C679

3-4 hr

Stain & Color Change

ASTM C510

No visible color change/No stain

Adhesion-in-Peel

ASTM C794

Aluminum 20-25 pli (89-112N)

Concrete 18-22 pli (80-98N) No Adhesion Loss

Effects of Accelerated Aging

ASTM C793

Pass

Movement Capability

 

+/- 35%

 

Expansion joints - The minimum width and depth of any sealant application hould be 1/4 in. by 1/4 in. (6 mm by 6 mm).The depth (D) of sealant may be equal to the width (W) of joints that are less than 1/2 in. (13 mm) wide. For joints ranging from 1/2-1 in. (13-25 mm) wide, the sealant depth should be approximately one-half of the joint width. The maximum depth (D) of any sealant application should be 1/2 in. (13 mm). For joints that are wider than 1 in. (25 mm) contact 96608333.

 

Window perimeters - For fillet beads, or angle beads around windows and doors, the sealant should exhibit a minimum surface contact area (C) of 1/4 in. (6 mm) onto each substrate. Proper joint backing or bond breaking should be provided to allow for anticipated movement.

 

Surface Preparations

 

Surfaces must be sound, clean, and dry. All release agents, existing waterproofing, dust, loose mortar, laitance, paints, or other finishes must be removed. This can be accomplished with a thorough wire brushing, grinding, sandblasting, or solvent washing, depending on the contamination. Tremco recommends that surface temperatures be 40 F (4 C) or above at the time the sealant is applied. If sealant must be applied in temperatures below 40 F (4 C).

 

Priming

 

Where deemed necessary, use Tremprime Silicone Porous Primer for porous surfaces and Ttemprime Silicone Metal Primer for metals or plastics. Dymonic FC typically adheres to common construction substrates without primers; however,

due to the variability of substrate finishes such as Kynar and anodized aluminum, Tremco always recommends that a mockup or field adhesion test be performed on the actual materials being used on the job to verify the need for a primer. A

description of the field adhesion test can be found in appendix X1 of ASTM C1193, Standard Guide for Use of Joint Sealants.

 

Application

 

Dymonic FC is easy to apply with conventional caulking equipment. Ensure that the backer rod is friction fitted properly and any primers have been applied. Fill the joint completely with a proper width-to-depth ratio and tool to ensure intimate contact of sealant with joint walls. Dry tooling is always preferred, although xylene can be used in limited amounts to slick the spatula if needed following the initial dry tooling. For a cleaner finish, mask the sides of the joint with tape prior to filling.

 

Cure Time

 

Dymonic FC generally cures at a rate of 3/32 in. per day at 75 F (24 C) and 50% relative humidity. Dymonic FC will skin in 1 hr and be tack-free in 3-4 hr. The cure time will increase as temperatures and/or humidity decrease. A good rule of thumb is one additional day for every 10 F decrease in temperature.

 

Clean up

 

Excess sealant and smears adjacent to the joint interface can be carefully removed with xylene or mineral spirits before the sealant cures. Any utensils used for tooling can also be cleaned with xylene or mineral spirits.

 

Limitations

 

Do not apply over damp or contaminated surfaces.

Use with adequate ventilation.

Do not use under polyurethane deck coatings unless the sealant is fully cured.

Always utilize the accompanying MSDS for information on Personal Protective Equipment (PPE) and health Hazards.

Although Dymonic FC is paintable, this does not imply adhesion to and compatibility with all paints 

 