Wrimco Waterproofing                              Home  | Specification | Product | Project | Technical data A-Z | Contact us

Adhesive Membrane

Anti-root Membrane

Approved Applicators

Backing Rod

Drainage Cell

Drainage Sheet

Epoxy Adhesive

Epoxy Flooring

Flat Roof Membrane  

Foundation Membrane

Liquid Membrane

Membrane Protection

Product Application

Product Category

Retaining Wall

SBS Sheet Membrane

Torch on Membrane

Under Slab Membrane

Vapour Barriers

Waterproofing Primer

 

Waterproof Balcony Liquid Membrane Waterproof Bathroom liquid membrane Waterproof Retaining Wall Liquid Rubber Membrane How to waterproof a bathroom Waterproof Internal Wet Area Membrane Waterproof Tiled Balcony Clear Penetrating Sealer Trafficable liquid membrane UV Protection liquid membrane Waterproof Water Feature liquid membrane Hydro Pressure Resistant liquid membrane Waterproof fish pond liquid membrane waterproof bathroom liquid membrane Waterproof above screed liquid membrane UV Resistant Polyurethane Membrane Waterproof leaking balcony liquid membrane waterproof damp basement wall liquid membrane Solutions to common waterproofing problems Maxseal Foundation Polyurethane Membrane MasterSeal M210TIX Latex Rubber Liquid Membrane Waterproof wet basement wall liquid membrane Injection Drill Pump Vulkem 350/345/346 Ardex WPM 300 Epoxy - Stop Rising Damp Waterproof Metal Roof Liquid Membrane Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer, waterproof Leaking Balcony, Flat Roof, Planter Box, Bathroom tradesman, handyman Waterproof Box gutter liquid membrane Waterproof Retaining Wall liquid membrane Waterproof Internal, External Wall Liquid Membrane Waterproof Concrete Slab Liquid Membrane Waterproof Balcony Liquid Membrane Stop Leaking Shower Liquid Membrane How to waterproof a retaining wall How to waterproof a Retaining Wall How to fix leaking fish pond Waterproof Garage Roof Liquid Rubber Membrane Waterproof water tanks for drinkable water Waterproof Leaking Roof, Gutters, Balcony, Car Park tradesman Waterproof leaking box gutters tradesman Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer   Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer   HiBuild Hydrastatic Water based Epoxy Hydrostatic Negative Pressure Water Based Epoxy Under tile screed bed waterproofing membrane Prevent and Fix Rising Damp Waterproofing Epoxy Waterproof exposed balcony liquid membrane Repair leaking balcony waterproof liquid membrane Waterproof Bathroom Liquid Membrane Planter Box Retaining Wall Tanking Liquid Membrane Waterproof Leaking Metal Roof Waterproofer HOw to repair leaking fish pond Waterproof Underground wall Liquid Membrane Waterproof Planter Box liquid membrane Waterproof Watertanks Cementitious Liquid Membrane Waterproof Lift Pit Liquid Membrane ARDEX WPM 001 - Undertile Waterproofing Membrane Waterproof Planter Box Root Resistant Liquid Membrane Repair Bitumen Roof Waterproofing Liquid Membrane UV Protective Polyurethane Membrane Waterproof External Brick Wall liquid membrane Waterproof Retaining Wall Liquid Membrane Waterproof Planter Box Liquid Membrane Waterproof Wet Retaining Wall Liquid Membrane Waterproof Leaking External Wall Licensed Waterproofer Emer Clad Acrylic Liquid Membrane Waterproof Planter Box, Retaining wall liquid membrane Fast Cure Elastomeric Waterproofing Membrane Systems Waterproof Leaking Swimming pool tradesman UV Resistant Acrylic Liquid Membrane How to Waterproof a Leaking Metal Box Gutter Sikalastic 560 - Repair Bitumen membrane Roof Waterproof Lift Pits Tradesmen Waterproof Leaking Kitchen Tradesmen Waterproof Leaking Internal Basement Walls tradesman Waterproof Leaking Laundry tradesman Waterproof Leaking Deck, Verandah Tradesman Waterproof Leaking Roof, Gutters, Balcony, Car Park Tradesman, waterproofer, license waterproofer Repair Bitumen Roof Liquid Rubber Membrane Waterproof Besser Block Wall with Liquid Membrane Waterproof leaking bitumen roof contractors Waterproof leaking bitumen roof contractors  Waterproof Leaking Retaining Wall, Basement Wall Tradesmen Waterproof Leaking Ceiling Waterproofer
Commercial Building Sheet Membrane Concrete Roof Sheet Membrane Waterproof Deck Sheet Membrane Entertainment building Waterproofing Membrane Waterproof Government Building Sheet Membrane Waterproof Hospital Building Sheet Membrane Waterproof Landmark Building Bitumen Membrane Waterproofing Planter Box Sheet Membrane Waterproof Plywood Roof Sheet Membrane Waterproof Residential Building Sheet Membrane Waterproof Roof Bitumen Sheet Membrane Waterproof Flat Roof Sheet Membrane Waterproof Retaining Wall Sheet Membrane Terrace waterproofing Sheet Membrane Waterproof University Building Sheet Membrane Wrimco Reference Waterproof Lift Pit Sheet Membrane Waterproof Concrete Roof Sheet Membrane Tanking Sheet Membrane Systems Vaucluse Waterproofing Project  Mosman Waterproofing Project Waterproofing Palm Beach Waterproofing Dover Height Waterproofing Darling Point Waterproofing Bellevue Hill waterproofing tradesman Knowledge Base FAQ Waterproofing Product Waterproof Leaking Garage Roof tradesman Repair SBS, APP Sheet Membrane Waterproof Concrete Slab Sheet Membrane Waterproof Leaking Garage Roof Liquid Rubber Membrane Waterproof Leaking Metal Roof Liquid Rubber Membrane Waterproof Balustrade Sheet Membrane Waterproof Commercial Building Project Bitumen Sheet Membrane Closed Cell Backing Rod Repair Crack Joints Closed cell backer rod Expansion joint backing rod Backing Rod Waterproof Leaking Roof, Balcony, Box Gutter tradesman Repair Leaking underground basement wall Waterproofer Waterproof Leaking Shower, Bathroom, Wet area Tradesman Repair Leaking Deck, Planter Box Waterproofer Waterproof Leaking Fish Pond Tradesman Waterproof Rising Damp Basement Tradesmen Roofs Waterproofed with Wrimco Sheet Membrane Waterproof Retaining walls with sheet membrane Waterproof Balcony with Sheet Membrane HDPE Self Adhesive Sheet Membrane Waterproof Commercial High Rise Building Roof Contractors Waterproof Car Park Roof with sheet membrane Ardex WPM 116 Sheet Membrane Ardex WPM 150 APP Sheet Membrane ARDEX WPM 188 SBS Garden Tanking Membrane ARDEX WPM 185 APP Sheet Membrane Ardex WPM320 Retaining Wall Sheet Membrane Waterproof Deck with torch applied Sheet Membrane ARDEX WPM612 FL TPO Fleece-Backed Roof Membrane TREMproof SBS 4000M Mineral Bituminous Membrane ARDEX WPM 1000 Weldable Waterproofing Membrane SBS Sheet Membrane Installation ARDEX WPM 3000X peel and stick membrane ARDEX WPM 750 Undertile Butynol  Waterproof Concrete Slab with Sheet Membrane ARDEX WPM 444 APP Sheet Membrane How to waterproof a Retaining wall How to waterproof a Planter Box How to waterproof a planter box How to waterproof Tiled Balcony with clear sealer How to waterproof a Shower  Ardex SRO 834 Waterproofing Specification Wrimco Sheet Membrane Waterproof elevator pits Sheet Membrane SBS Sheet Waterproofing Membrane How to waterproof balcony with sheet membrane Anti Root Sheet Membrane Vehicular Traffic Liquid Membrane Waterproof Planter Box with torch applied sheet membrane Waterproof Balconies Decks Podiums Prevent Rising Damp Hydro Static Epoxy How to waterproof a planter box 

Waterproof fish pond liquid membrane: 

Duromastic Duropond double crosslinked copolymer membrane for pond waterproofing  

AS4858:2004 compliant - CLASS III  

DURO MASTIC DUROPOND is a liquid membrane product based on a unique double crosslinked copolymer system. The product is water based yet offers strong water resistance. The cured membrane has exceptional flex and elasticity for good crack-bridging properties while at the same time maintaining good tensile film strength. DUROPOND has excellent resistance to UV, colour fade and chalking. DUROPOND is easily maintained, recoated and re-paired .The water content is low which enables fast drying, and thick films to be built up quickly. The product is supplied as a thixotropic liquid, which is easily applied to both vertical and horizontal surfaces. It complies fully with the test requirements of AS:4858-2004 "Wet Area Membranes" and passes at Class III, the highest level in the Australian standard. DUROPOND is applied as part of a system with primer Duromix Hibuild WBE.  

PRINCIPLE CHARACTERISTICS

  • Single component, water-based
  • Excellent water resistance
  • UV resistant
  • High Solids
  • Ease of application - roller/brush
  • Good adhesion
  • High elongation
  • Non-hazardous, low odour
  • Does not bleed, non-staining
  • Low VOC & Green Building Council compliant                     

PACKAGING 15 Litre  

User Areas

Water features,  Ponds,  Fountains & bird baths, Tanking  

Technical Information:  

  • Colour: Black, (Blue and other colours on request)
  • Weather Resistance: Excellent, pass +1000 hrs QUV Weather meter, 2000 hrs UVa
  • Dry Time: 2-4 hours @ 25 C, 50% R.H.
  • Recoat Time: 4-6 hours @ 25 C, 50% R.H.
  • Coverage: Total 2.0 litre/m2 min. Apply as 2 or more coats, each coat at 1.0 litre/m2
  • Dry Film Thickness: 1.2 mm minimum
  • Elongation: + 600% @25 C
  • Tensile Strength: 1.4MPa @25 C
  • Solids Content: 60% by volume
  • Shelf Life: 8 months in unopened containers @ 20 C
  • VOC: 9.0 g/L Green Building Council Compliant                     

INSTALLATION

Within ponds and tanks under construction, the air and surfaces tend to be colder and more damp than surrounds. This and the fact that the air is not moving much will slow drying and curing, especially in cooler or wetter months. It is essential to allow time for the primer and DUROPOND to dry thoroughly between coats. In winter & autumn, application in the warmest part of the day is recommended. Drying can be accelerated by fans or heaters. Do not apply Hibuild WBE primer or DUROPOND below 10 C ambient. Do not apply DUROPOND above 30 C. Do not apply during wet weather conditions, or if rain is likely.  

SURFACE PREPRATION

Good surface preparation is essential for optimum performance. Ensure water features, ponds and tanks are structurally sound and free of cracks. In below grade locations with a high water table, it is recommended to waterproof the positive (earth) side of any blockwork construction) with Duroproof PU Black or Duro Mastic BLW. This will reduce seepage of water and salts to the inside surface where the primer will later be applied. Blockwork construction must be prepared so that the cavities are completely filled, all mortar joints are filled and flush and the surface is as smooth as possible, i.e. free of sharp edges, pits, gaps, grit and mortar residues. Preferred is 20mm to 30mm of sand and cement render over the blockwork. Remove all dust, loose particles, contaminants and curing compounds. If necessary water-blast unsound or powdery concrete surfaces. Concrete must have a minimum strength of 20MPa and be cured a minimum of 28 days. It is best if the surfaces are dry as possible before priming. Slight dampness may be tolerated initially, provided the primer can thoroughly dry after application. Before applying Hibuild WBE primer and DUROPOND, any problems from rising damp, continual wetness or hydrostatic pressure must be remedied.  

PRIMING & DETAILING

Prime the interior with 2 coats of Duromix Hibuild WBE as detailed in the product's technical data sheet. It is essential that the application of the primer is carried out correctly. For blockwork or porous surfaces dilute the mixed Hibuild WBE with water up to 10% and 'work' the product into the surface so that all pores and pinholes are filled and sealed. Apply a further one to two undiluted coats until no pin-holes are visible and an even solid coat is formed. Allow the final coat of primer to dry thoroughly, i.e. at least 24 hours in summer and up to 72 hours in cool to cold conditions. Next, apply Durotech Fast Cure PU Sealant at all horizontal and vertical junctions such as floor to wall, and wall to wall. Apply a neat smooth fillet about 12mm by 12mm. Remove all sealant residues and overhangs. The sealant can be coated after a good skin has formed (approx. 1 hour).  

APPLICATION

Ensure that the primer is thoroughly dry and cured. Apply DUROPOND by brush or roller in at least two or more coats to achieve a total minimum dry film thickness of 1.2 mm. Do not apply in one thick coat. In cold conditions it it may be best top apply as 3 thin coats or accelerate drying by fans or heaters. Allow to dry as long as possible between coats, then check for pinholes and thin areas, and recoat if necessary. If the membrane becomes dirty or damaged between coats, clean with water and recoat. Spills and tools should be cleaned with water before DURPOND has dried.  

Maintenance

Coating maintenance is based on regular inspection and then timely repair of any damage and deterioration by thorough cleaning using a little sugar soap and water, followed by thorough rinsing. When dry, apply DUROPOND

 